This is related to the serial com connections that are used. It is being practiced by thousands of pool owners just like you. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. Check flow/temp/salinity sensor cable for damage. Zodiac Brand Item Number R0467600. We had to replace the filter and pump body! It is ok to startup the chlorinator when there is a little bromide in the pool. Here is a test you can do to diagnose the trisensor. * Pricing, promotions and availability may vary by location and at lesliespool.com. Air, pool water, and SWG pool water. You know what? Jandy AquaPure 1400 Chlorine Generator Quick Specs View Detailed Specs Power: 1.25 lbs/day 90-Day / 1 Year Limited Warranty 8000 Hours Rated Lifespan 40000 Gallons Max Capacity Description Reviews Specs Controls Cell Warranty "The Heavy-Duty Standard for Maximum Performance" It uses 240V and 50/60hz Export. Measures 6-inch diameter by 14-inch width by 9-1/2-inch height. We are sorry. This can usually be prevented by sealing the stone with a sealer. See Section 4.5 of the owner's manual. 2023 Zodiac Pool Systems LLC - All rights reserved. 2 - Screws, Power Interface. No instructions contained w/unit. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. This AquaPure foundation power center pack is designed to se with Zodiac Jandy AquaPure PureLink cell kit. It has 1 year manufacturer warranty. Brush down the affected walls and follow the directions in Section 5.4.1 of the owner's manual, Shocking. Will there be any harm if someone swallows salt water in a salt chlorinated pool? The Jandy AquaPure Power Pack uses a process known as electrolysis to produce sodium hypochlorite (liquid chlorine) from a low concentration of salt added to the pool water. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. Press and hold the test buttons marked salinity and R-temp. New, not old stock, in sealed box. Drop in the Best When You Replace the Rest. Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Get 1 point for every $1 spent. Brief content visible, double tap to read full content. Your panel uses the tri-sensor in the saltwater chlorine generator. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Only 17 left in stock - order soon. Different Water Temperature Readings on Jandy Aquapure Control Center 99. Do I still need to use granular chlorine with my Salt water chlorinator? If chlorine output at lowest setting is still excessive then the salt water chlorinator system is oversized for the pool. The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center Power Interface Board (PIB). If so, why the 2 different readings? If burnt connector contact authorized service representative. Guess we will this year. In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). Recheck. Changes to Aquapure settings made on Aqualink will not show on the Aquapure and the chlorine% will be 0. In the event no such state or local requirement exists, the installer and maintainer must be a professional with sufficient experience in pool equipment installation and maintenance.". 1-800-537-5437. Use Up and Down arrow keys to navigate search results. Q: Will salt from the salt water chlorinator deteriorate the metal components in my pool? Jandy makes the Purelink Power Center that combines the Aqualink and Aquapure controls in one cabinet. This page was last edited on 21 November 2022, at 19:29. Either a short wait or a reboot resolve this. Amazon has encountered an error. Car & Truck Safety & Security Accessories, DEWALT DCCS620B 20V MAX Cordless Li-Ion 12 in. Look at the label on the CPU for the firmware revision. The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. The only hiccup we get, is an occasional communication error. After installing began to flash code of 181 & 172. The salt under the effect of electrolysis, is transformed into sodium hypochlorite, a disinfectant. Plug flow/temp/salinity sensor into connector on power center printed circuit board. $299.99. Rely on its sturdy design and simple features to create your saltwater oasis. Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. Asked on 5/16/2017by Steve. Check connection. 2) Order your Power Center. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. ORP / External Control Interface 2. It appears that Aqualink stops talking to Aquapure when the Aqualink water temperature sensor is inoperative.[12]. For a better experience, please enable JavaScript in your browser before proceeding. Clean if necessary. Or just the control box? Increase the system operating time per day. See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. Cell trisensor senses temperature, salinity and flow. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). Thank You. Rely on its sturdy design and simple features to create your saltwater oasis. See Section 4.7 of the owner's manual. Replace the Power Cord When you Replace the Cell, Replacing Old Square Jandy PLC700/1400 Cell, AquaPure Resets to 35% Everytime it is Powered On, AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual, Jandy AquaPure, PureLink & Nature Fusion Soft Workbook, https://www.troublefreepool.com/threads/need-intelliflo-and-jandy-aquapure-1400-folks.254612/post-2226671, https://www.troublefreepool.com/threads/plc1400-and-r0452400-compatible.260746/#post-2280305, https://www.troublefreepool.com/threads/six-month-old-jandy-plc1400-smoking-melting-rubber-wire-connector.198600/post-1752937, https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf, https://www.troublefreepool.com/threads/aquapure-cycle-time-wiki-correction.264622/#post-2321916, http://viewer.zmags.com/publication/1a29b06c#/1a29b06c/892, https://www.troublefreepool.com/threads/when-did-jandy-declare-war-on-diy.176586/post-1558946, https://www.troublefreepool.com/threads/jandy-old-square-salt-cell-replacement.201262/, https://www.troublefreepool.com/threads/jandy-aquapure-1400-error-120.236117/, https://www.troublefreepool.com/threads/aquapure-1400-receiving-error-code-123.46288/post-387518, https://www.troublefreepool.com/threads/jandy-aquapure-plc-700-not-producing-chlorine.220478/post-1929929, https://www.troublefreepool.com/threads/will-a-new-water-temp-sensor-fix-this-aquapure-swg-scenario.243392/, https://www.troublefreepool.com/threads/jandy-pda-wasnt-displaying-aquapure-info.194647/post-1715658, https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853, https://www.troublefreepool.com/threads/jandy-power-center-transformer-replacement-aquapure.194422/, https://www.troublefreepool.com/wiki/index.php?title=Jandy_AquaPure_SWG&oldid=5928, PURE700 - 0.625 lb./24 Hr. See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. Select your subscriptions from a range of popular titles. The Jandy Versa Plumb System delivers the highest energy efficiency through its innovative design that maximizes hydraulic integrity. Check the water balance as usual. AquaPure Salt Water Pool System | Jandy Zodiac R0403200 Control Box Cover Replacement for Zodiac AquaPure Pool guy installed quickly and it is working great. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). To avoid clogging the filter or damaging the control center and pump, do not add salt through the skimmer, main drain, or surge tank. We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. $195.99. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. For all your hard to find pool and spa parts, including above ground spa parts, , Copyright 2023 Pool and Spa Parts Depot. Is it true that a salt water chlorinator provides chlorine-free water? You have 3 temp sensors. Turn power to unit off and back on (Cycle Power). Is it true that salt water chlorination is maintenance free? Not reliable at all and have had problems starting about 1 month after installation. Find many great new & used options and get the best deals for E1 Jandy PLC1400 AquaPure 3-Port Salt Water Pool System at the best online prices at eBay! Sitemap | Ensure there is no loss of pump prime or clogged strainer baskets. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. If the actual salinity is above 4.0 gpl (4,000 ppm), the pool needs to be diluted to get the level below 4.0 gpl. Why You Should Only Work With A Qualified Professional. Be the first to review this product! Haha! Free shipping for many products! Provide your account email address to receive an email to reset your password. In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. Determine the amount of salt necessary to add from an appropriate chart. That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. (Cycle Power). You are dealing with 240 Volts and electrical circuits. Please try again later. Any new postings here are unlikely to be seen or responded to by other members. Please note: This item is only available for in-store pickup and the selected store is out of stock. The arrow points to the water temperature sensor. You can remove the two screws holding down the plate over the prongs and check the base of the prongs. Jandy Zodiac R0468501 Aqualink RS8 P&S Power Center Board . The production cycle time used for chlorine production (observationally) is 30 minutes. Jandy Aqualink RS : Swimming Pool Automation | Pool Supply Unlimited For very hard water, some chlorinators can shorten the polarity inversion time (e.g. Pool and Spa Parts Depot | Swimming Pool Supplies. The basic Jandy Aqualink RS System involves FIVE key elements: 1) Order your System Level. Please select a nearby store with available inventory to process your order. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. Ideas on how to resolve this issue? Consult your pool professional regarding use of a sequestering agent. The purer the salt, the better the life and performance of the electrolytic cell. I couldn't get one of the screws on the power panel off, Help Support TFP Trouble Free Pool is run by a dedicated group of volunteers that Read more, Hello , This is an inactive thread. Test salinity. All other firmware uses program B on the trisensor inline module. It's always important to test the salinity before adding salt to determine how much salt should be added. If the unit is not correctly installed you may get severe electrical shock or you may fry the system. Press the Salinity button and hold it until it beeps 3 times. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. Can I switch from bromide to salt water chlorination using the same water? This is not a DIY product. Check that ribbon cable is fully inserted into connector. With the AquaPure 1400, the reading is in grams per liter, which is the same as 1,000 ppm. iAqualink 2.0 is Wi-Fi for the Aqualink system. Add To Cart. Salt Water Pool Generator Control Center Model# APUREM Retail is $1000 Follow cleaning procedures. You will also find the cell sold alone at a lower price then the kit and it is tempting to buy only the cell. Is this unit a compatible replacement for an Aquapure 1400 control? After 24 hours, verify correct salt reading. The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. Add salt as described in Section 4.7 of the owner's manual. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Most cases of corrosion can be better explained by an incorrect water chemistry as opposed to the presence of salt. Scale formation on pool equipment. 2 for when the cell is installed and 1/2 of the other 2 unions (the "male" 1/2) for creation of the bypass pipe. $200 later guy said unit was shipped without a translatetor card???? Rather than swapping my existing power center for 6613-AP (no breakers), I prefer to add an APUREM subpanel power center and run the four-wire harness over to the iAquaLink board. Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 - eBay Am I correct in assuming that the box contains the internal components such as the control, A: Used On Jandy AquaPure and ClorMatic Metal Control Box Systems. Add stabilizer to maintain 50 - 75 PPM per pool professionals recommendations. There are numerous sites that have detailed information about the install. There are beads at the bottom of my pool, what does it mean? No instructions contained w/unit. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. Remove cell for inspection. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. Choose from Pool and Spa Combo Systems. The Flow & Salinity Sensor is Jandy P/N R0452500. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. 1 - Face Plate, Control Center, APUREM. Winterize your pool. Manufacturer SKU: 6967+. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. $200 later guy said unit was shipped without a translatetor card???? Then adjust pH to within the range 7.4-7.6. The percentage setting will control how much the cell runs during the production cycle.[5]. It is being practiced by thousands of pool owners just like you. Rely on its sturdy design and simple features to create your saltwater oasis. Manually shock the pool following the directions in Section 5.4.1 of the owner's manual, Shocking. See Section 6.3, Step 2 of the owner's manual. JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 - Pool and Spa Parts 96. For all your hard to find pool and spa parts, including above ground spa parts, Add salt as described in Section 4.7 of the owner's manual. Amazon.com: Zodiac R0403200 Control Box Cover Replacement for Zodiac AquaPure APURE1400 Plastic Control Center : Patio, Lawn & Garden . Regular Price: $212.61. E1 Jandy PLC1400 AquaPure 3-Port Salt Water Pool System Wichita Falls, TX. See Section 5.4 of the owner's manual, Startup. Water conditioning salt pellets take longer to dissolve. Is it possible to use salt water chlorination when the pool liner is in natural stone? ORP / External Control Interface 2. Please consider. If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. However, if you have any doubts, do not try this!!! It may not display this or other websites correctly. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual. A separate communication will follow . Reviewed in the United States on December 6, 2014. Zodiac Jandy AquaPure Salt Cell Flow & Salinity Sensor |R0452500 Consult your salt supplier. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. Being relatively adept, I chose to install this myself. Includes: 1 - Power Interface Board Assembly. See Section 4, Table 2 of the owner's manual. You need to determine the correct Revisio, Q: We will contact you as soon as this product is available. Disconnect the flow salinity temp sensor from the front board. Test salinity by pressing the Test Salinity button. Methods: A cross-sectional observational study was performed in the Intoxication Control Center of the Sao Paulo City Hospital. The remaining bromide will not harm the users, pool equipment or the pool. Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. No warranty when purchased online. The LCD should read 2.8 gpl*. | IQ20-A. Do Not Sell or Share My Personal Information. Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. Perks can be redeemed online, in store or in the Leslies app. Jandy AquaPure Power Supply - APUREM - INYOPools.com Apple is not a participant or sponsor of this promotion. Shop Online or at any of our 900+ retail stores! Hypochlorite kills bacteria, oxidizes organic material, and kills algae then reverts back to salt. Control CenterThe control center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis. Check that unit is correctly wired for 240 VAC and connected to 240 VAC. They are sold as a kit.[2]. The LCD should read 91 F or 33 C . All other forms of chlorine (tablets, powder, liquid, etc.) If the unit reads 2.8 gpl for salinity, then the unit has not been recalibrated. 120 is low current. PDF WARNING - bestbuypoolsupply.com In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. Had to down load from another site. This is why changing this parameter is reserved for the pool professional. We promise to never spam you, and just use your email address to identify you as a valid customer. Sorry - Air temperature sensor. It looks like WhatsApp is not installed on your phone. #1. Jandy AquaPure 1400 Chlorine Generator | DSP - Discount Salt Pool Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. FREE delivery Feb 16 - 21 . To Enter Boost Mode Press and Hold Temperature Button 10 Seconds, Here is an excerpt from page 423 (892)[6] of their 2019 catalog:[7], "This Jandy Limited Warranty does not apply to Jandy branded products purchased through the Internet or other e-commerce platforms, with the exception of Jandy branded valves, parts, and accessories. Refer to Maintenance Procedure for acid wash cleaning. Currently, Jandy has part R0481400 which is the round transformer. Power Center Compatible with Pentair IntelliChlor Pool, APPLIAFIT O-Ring Compatible with Jandy Zodiac R0357800 for CL, CV, DEL & DEV Series Filters (2-Pack), Tier1 Pool & Spa Filter Cartridge | Replacement for Dimension One 1561-00, Pleatco PDO75-2000, FC-3059, C-7367, Aladdin 17541 and More | 75 sq ft Pleated Fabric Filter Media, POOLPURE PDM28 Spa Filter Replaces Aquarest Dream Maker 461273 Hot Tub Filter, 2 Pack, SpaO2 Swimming Pool Aerators - Set of 2, ABS Injection Molding, Fit 1-1/2 FIP/MIP Threaded Return outlets, MAX Depth 19.7, Raise pH Without Changing Alkalinity, Crystal Clear Water, Less Chemicals, 1996-2023, Amazon.com, Inc. or its affiliates, Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Zodiac Jandy AquaPure PureLink Cell Kit. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. This method would require the purchase of 4 unions. The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. See Section 6.3 of the owner's manual, Electrolytic Cell Cleaning. However, when I power on the AquaLink PDA, it shows the water temp is 120 degrees. Is there only 1 water temperature sensor? Jandy's replacement Power Center Transformer works with the AquaLink RS and AquaPure automatic control systems. Pricing and offers are subject to change. You can remove your cell for winter and install the dummy cell. No, a pool treated by salt water chlorination is a chlorinated pool in which the chlorine is produced automatically. Had to down load from another site. The PureLink DC Cord is Jandy P/N R0402800. It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. Use a salt that is at least 99.8% pure NaCl. See Section 5 of the owner's manual, Operating Instructions. The cell cannot be repaired even though the plates may have life left in them. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. Turn the chlorinator off or reduce the chlorine production percentage to zero. Sign up now. However, the Jandy PLC700 cell kit (for pools up to 12,000 gallons) and the PLC1400 (with a 40,000 gallon capacity) kit contain new cells as well as all the necessary accessories to switch a 2-port setup to the new design.[8]. High salt concentration above 4.0 gpl may damage the power center. Would recommend it to anyone needing a replacement or installinf for the first time. It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. good documentation. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. Note: The salinity or salt level should always be tested before salt is added to the pool. It may not display this or other websites correctly. The flow portion of the Flow/Temp/Salinity Sensor is a backup device only. Remove cell for inspection. >PoolAndSpaPartsDepot.com is Open for Business! Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. Jandy AquaPure Control Center Replacement Parts - Poolweb This aquapure is use with PLC700 or PLc1400 for salt system only. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. The cartridge must be replaced. You can recalibrate the unit if you are really sure about the actual salinity and you want the box to match your readings. Please try again. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. This may be necessary after heavy rains, backwashing and refilling, excessive splash out, etc. Replacing a Jandy Aquapure with???????? - Trouble Free Pool This issue is with the trisensor, which is a separate part that installs in the cell. In addition, chlorine levels can be stabilized easier with less dramatic fluctuations. [14] After discussions with a Jandy representative it was determined the problem was a bad board. Brush the pool bottom and allow water to circulate for 24 hours to dissolve salt completely and mix evenly Reviewed in the United States on April 8, 2017. Super Chlorinate Pool. The Jandy AquaPure, PureLink & Nature Fusion Soft Workbook gives a lot of good information on installation and troubleshooting.